OpStar İnfusion Pump WIT-601A

OpStar İnfusion Pump WIT-601A

- Fast value setting with the keypad
- Ability to record sets, quick selection
- Sorting treatment with gradual mode
-Ability to send automatic bolus

Speed that can run in 6 different smarter modes; time, patient records; Drug Library
Programmable sequential infusion, ability to reduce or increase the speed when running pigyback
More useful: open system can be used with all universal sets
Digital keyboard and menu whose values can easily be adjusted 
More secure double process lock mechanism; antireverse feature More comfortable: Liquid heater (Optional)
 FEATURES
INFUSION SET OPTIONS: CAN ALSO BE USED SET-DEFINED IF DESIRED
10d/ml, 15d/ml, 20d/ml,
60d/ml(3.4mm 4.5mm) 
INFUSION MODES: SPEED MODE; TRICKLE MODE; TIME MODE; SEQUENTIAL
PROGRAMMING MODE; WEIGHT (DOSE MODE); DRUG LIBRARY MODE
STANDARD DEVIATION ERROR VALUES: MAXIMUM ± 5% FLOW RATE: 0.1 ~ 1200ml/hour (20 d/ml IV set)/1 ~ 150 ml/hour (60 d/ml IV set)
ALARMS: Air bubble; door open; completed; Stopped; Time-out;
Empty, leakage, battery damaged, motor control, unidentified infusion set,
drop sensor error, fuser error, upper track congestion, lower track congestion,
connection error
CONGESTION PRESSURE: Upper Pressure Standard; Lower Pressure Adjustable
Value High 70-90KPA; MEDIUM 55-70KPA; LOW 40-55KPA
DROP MODE SPEED: 1 ~ 400 drop/min (20 drop/ml IV set) 1 ~ 150 drop/min. (60DROP/ml IV set) PROCESSOR: DUAL CPU
ADJUSTABLE TOTAL DOSE: 1-9999ml LOCK: AUTOMATIC LOCKING AGAINST UNAUTHORISED INTERVENTION
LANGUAGE: ENGLISH RUSSIAN TURKISH PROGRAMMING: Infusion treatment, eights-stage, programmable 
KVO 1ml/hour DRUG LIBRARY: The user can define medication up to 100 pieces
Purge 600 ml/HR PATIENT RECORDS: Ability to transfer 1500 patient records to computer through LAN
BOLUS: Opening value 600 ml/hour, total 2 ML, values can be increased if desired PIGGYBACK: can be increased while speed is running without stopping the device.
AIR BUBBLE DETECTION: Ultrasonic detector can set values. 50 ~ 800μL FLUID HEATER: Optional
Battery: 7 hours of duration, to full charge in 12 hours, CHARGING APPARATUS SUTITABLE FOR AMBULANCE DC 9.6 V, 2000mAh; DIMENSIONS: 130 mm × 120 mm × 195 mm
Weight: 2 KG
OPERATIONAL CONDITIONS: TEMPERATURE 5 °C ~ 40 °C HUMIDITY 20% ~ 90%
PRESSURE: 70 ~ 106KPa
APPLICABILITY: Any fluids and medications in micro or rapid intravenous
ELEKTİRKSEL SAFETY CLASS: Class I with inner power, Ipx4, CF
POWER SOURCE: AC: 100V ~ 240V, 50 Hz/60 Hz; Power dissipation: 25VA